SEU CABLE
PRODUCT DESCRIPTION
Built with compact-stranded AA-8000 series aluminum alloy conductors insulated with XLPE and enclosed in a sunlight-resistant gray PVC jacket, it provides a cost-effective, code-compliant solution for conveying power from the service drop to the meter base and from the meter base to the distribution panelboard.
Standards
UL 44 · UL 854 · ASTM B-800 · B-801 · NEC NFPA 70 · Federal Specification A-A-59544 (JC-30B NEC) · NEC Article 338
Conductor
Compact-stranded AA-8000 series aluminum alloy per ASTM B801 or B836 · Single conductors UL Listed Type XHHW-2
Insulation
XLPE (cross-linked polyethylene), Type XHHW-2 · 90°C wet and dry locations · 600V
Assembly
Insulated phase conductors cabled together with an aluminum alloy concentric neutral, covered with a reinforced binder tape
Jacket
Sunlight-resistant gray PVC · Sequential footage markings
Conductor Identification
2-conductor: Black phase · Black/Triple Red Stripe neutral
Standards
UL 44 · UL 854 · ASTM B-800 · B-801 · NEC NFPA 70 · Federal Specification A-A-59544 (JC-30B NEC) · NEC Article 338
Conductor
Compact-stranded AA-8000 series aluminum alloy per ASTM B801 or B836 · Single conductors UL Listed Type XHHW-2
Insulation
XLPE (cross-linked polyethylene), Type XHHW-2 · 90°C wet and dry locations · 600V
Assembly
Insulated phase conductors cabled together with an aluminum alloy concentric neutral, covered with a reinforced binder tape
Jacket
Sunlight-resistant gray PVC · Sequential footage markings
Conductor Identification
2-conductor: Black phase · Black/Triple Red Stripe neutral
-
seu cable
-
descriptionLegacy Wire’s aluminum SEU (Service Entrance Cable, Style U) delivers reliable single-phase power for above-ground residential and light commercial service entrance applications rated up to 600V. Built with compact-stranded AA-8000 series aluminum alloy conductors insulated with XLPE and enclosed in a sunlight-resistant gray PVC jacket, it provides a cost-effective, code-compliant solution for conveying power from the service drop to the meter base and from the meter base to the distribution panelboard.
-
applicationsSEU is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard, and may be used in all applications where Type SE cable is permitted. The two-conductor configuration is the standard choice for single-phase, two-wire residential service entrance connections and panel feeder runs in apartments, multi-unit dwellings, and light commercial buildings. Rated 600V for use in wet or dry locations not exceeding 90°C. Note: SE cables are not permitted for underground installation, with or without a raceway, per NEC 338.12(A)(2).
ADDITIONAL WIRE SOLUTIONS
Precision-engineered electrical wire products designed for reliability and performance in every critical connection.